Direct measurement of concrete permeability by flow

For the direct measurement of the permeability of concrete by the flow method, a test cell is required that is similar, in principle, to the modified triaxial cells used in standard soil and rock mechanics tests.

jonnyhough

jonnyhough

Rapid migration test

There are indications that this test is less variable than the Rapid Chloride Permeability testing RCPT and unaffected by different cementitious materials and conductive admixtures.

jonnyhough

jonnyhough

Measuring gas permeability

Gas permeability tests measure the flow of a gas into the concrete under the action of a pressure gradient.

jonnyhough

jonnyhough

Standpipe test

The standpipe test is one of the simplest tests for measuring the water absorption characteristics of concrete.

jonnyhough

jonnyhough

Carbonation of concrete

Phenolphthalein

To test for depth of carbonation into a concrete surface, a solution of phenolphthalein indicator can be applied. Uncarbonated concrete is indicated as a pink colouration i.e. the pH is greater than ~9. 

jonnyhough

jonnyhough

Cube dimensions and strength

The concrete structural code Eurocode 2 (BS EN 1992) is based on cylinder compressive strength. A relationship between the strength of 150mm diameter cylinders of 300mm length and 150mm cubes is given and is adopted by EN 206. In the UK, BS 8500 states that the compressive strength of 150mm cubes and 100mm cubes are considered equivalent.

jonnyhough

jonnyhough

Permeability testing

The permeability of concrete to liquids, ions and gases is of direct relevance to both durable concrete and to leak-resistant concrete for containment. Analytical models used to predict the age at which corrosion of the reinforcement will be initiated require a detailed knowledge of the transport mechanisms involved and the permeability of the concrete. Some specifications for projects in extreme environments (e.g. the Middle East) or requiring very long lives (e.g. railway tunnels) have specified permeability criteria, based on some form of analytical durability model, to be verified by testing the supplied concrete or precast concrete elements. A simple permeability test could form part of the quality assurance (QA) scheme for any precast concrete element, to check on the variability of standard units.

jonnyhough

jonnyhough

Chloride ion concentration

In chloride-contaminated concrete, it is necessary to determine the concentration of chloride ions at various depths in order to determine the likelihood of corrosion of the reinforcing steel. To do this dust samples (see separate entry) are taken from increments of depth (say 5 to 25 mm, 25 to 50 mm, 50 to 75 mm etc). Note that the first 5 mm drillings are normally discarded as being non-representative. The sample should consist of a minimum of 25 g of dust at each depth to be representative. Care must be taken to ensure that all the drilling dust is collected as studies have shown that more chloride is contained in the finer component of the dust.

jonnyhough

jonnyhough

Linear polarisation resistance

Measuring the polarisation resistance of reinforcing steel is one of the few methods of assessing corrosion rate, with the current density being related to the rate of loss of metal. Although well tried and tested in the laboratory the technique is not as frequently used in the field as half-cell potential and concrete resistivity.

jonnyhough

jonnyhough