Skip links

Archive

K Slump

The K Slump test is covered by ASTM C 1362.

jonnyhough

jonnyhough

Vebe test

The Vebe test is described in BS EN 12350-3:2009 Testing fresh concrete – Part 3: Vebe test.

jonnyhough

jonnyhough

Compacting factor test (BS 1881: Part 103)

The compacting factor test is described in BS 1881: Part 103 Testing concrete. Method for determination of compacting factor. This has now been withdrawn and replaced by BS EN 12350-4:2009 Testing fresh concrete: Part 4 Degree of compactability.

jonnyhough

jonnyhough

Degree of compactability test

The degree of compactability test is described in BS EN 12350-4:2009 Testing fresh concrete: Part 4 Degree of compactability which replaces BS 1881: Part 103 esting concrete. Method for determination of compacting factor.

jonnyhough

jonnyhough

Ball penetration test (Kelly ball)

This is a simple field test to measure workability by determining the depth to which a 6 inch (150mm)diameter metal weight 30lb (~13.6kg) will sink under its own weight in to fresh concrete. It is a popular test in America but not now used in UK.

jonnyhough

jonnyhough

Two-point test (rheology of fresh concrete)

Fresh concrete can be considered to behave as a Bingham plastic i.e a viscoplastic material that behaves as a rigid body at low stresses but flows as a viscous fluid at high stress.

jonnyhough

jonnyhough

Identity testing for strength in accordance with BS EN 206 and BS 8500-1

The responsibility for demonstration of conformity of concrete supplied in accordance with the Standard for concrete, BS EN 206, is placed upon the concrete supplier. BS 8500-1 strongly recommends that the producer holds third-party certification, e.g. QSRMC or BSI to provide an independent audit on conformity.

jonnyhough

jonnyhough

Concrete consistence slump test apparatus

Consistence tolerance – slump test

Consistence, measured using the slump test (BS EN 12350-2), is either specified as a class or target. Although a supplier will endeavour to provide the required value or range, deviations in production and sampling apply. The following tables give the maximum allowable deviation based on a spot sample taken from the initial discharge of a ready-mixed concrete truck.

jonnyhough

jonnyhough

Cubes – general

It is a standard quality control procedure to make test cubes from the fresh concrete, which are then stored under controlled conditions and tested (generally at an age of 28 days). Procedures are given in relevant parts of BS EN 12390, Testing hardened concrete, which&nbsp

jonnyhough

jonnyhough

The Concrete Society

The Concrete Society is an independent membership organisation that exists to promote knowledge and support the advancement of concrete.