For sole traders, students and anyone interested in concrete.

Repair of fire damaged structures
Most fire-damaged structures can be successfully repaired, this being the more cost-effective solution than demolition and reconstruction. Before carrying out any repair it is necessary to determine the extent of the damage to the concrete, and hence how much must be removed and replaced. Similarly the effect on the reinforcement must be determined and hence the requirement for any additional steel. These aspects are covered in the separate entries

Assessment of fire-damaged structures
Most fire-damaged structures can be successfully repaired, this being the more cost-effective solution than demolition and reconstruction. Before carrying out any repair it is necessary to determine the extent of the damage to the concrete and reinforcement and hence their residual strengths. Guidance on assessment is given in Concrete Society Technical Report 68, Assessment, design and repair of fire-damaged concrete structures.
Repair Guidance Notes
A Series of Repair Guidance Notes has been prepared by the Joint Liaison Committee of the Concrete Society, Institute of Corrosion and Corrosion Prevention Association. The aim of these Notes is to guide consultants and contractors through the application of BS EN 1504, Products and systems for the repair and protection of concrete structures, and other related concrete repair standards for the evaluation, design, specification and concrete repair process. The Notes will help ensure that appropriate materials are correctly specified and applied. 
Effect of induced vibration
When concrete repairs are carried out close to a source of vibration, for example on a bridge deck with traffic still running on an adjacent carriageway, there may be concerns that the vibrations may affect the concrete properties. It has been suggested that the strength development may be affected as well as the bond between the new concrete and old concrete and the bond with the reinforcement.

Externally bonded FRP – Applications
Typical applications for strengthening concrete structures with FRP are listed below.
Externally bonded FRP – Inspection
FRP strengthening systems for concrete structures must be correctly specified for the anticipated loadings and environment. In addition appropriately trained staff must be used to install the materials. It is important that all stages of the process are monitored and that the strengthened structure is inspected regularly when in service.

Externally bonded FRP – Columns
Fibre composites (FRPs) are widely used to strengthen columns. The most common technique is to impregnate sheets or strips of fabric (either carbon, aramid or glass) and wrap them around the column, building up the layers until the required thickness is achieved. This provides hoop restraint to the concrete in the column, increasing the load-carrying capacity. Fabrics may also be applied longitudinally, increasing the bending capacity of the column. A major advantage of the technique is that the dimensions of the column are not significantly increased.
Externally bonded FRP – General
Externally bonded fibre composite materials (FRPs), consisting of carbon, glass or aramid fibres combined with a suitable resin, are widely used for strengthening concrete structures. The materials may be preformed into composite plates or shells, which are then bonded to the concrete surface. Alternatively, the composite may be formed in situ, with the fibres in the form of fabrics impregnated with resin and applied to the concrete surface.
Surface coatings
Coatings may be used as part of the repair process to provide additional protection to both the existing concrete and the repair. They have a limited life and must be maintained if they are to remain effective. They can slow down the corrosion process by reducing carbonation and ingress of chlorides and moisture, and cutting off the supply of oxygen to cathodic areas. There are many different types of coating generally grouped into three main categories.