Skip links

Archive

Specification – Post-tensioned flat slabs

UK CARES has published a Model specification for bonded and unbonded post-tensioned flat slabs. This model specification offers guidance to organisations that are producing specifications for bonded and unbonded post-tensioned flat slabs and slabs with beams not more than 1m deep containing monostrand or flat tendons. Where appropriate notes for designers are given, though these do not form part of the specification.

jonnyhough

jonnyhough

Grouting of post-tensioned tendons

The grouting of the ducts surrounding post-tensioning tendons provides the necessary mechanical connection to transfer the stresses between the tendons and the concrete and also protects the tendons from corrosion. The latter is particularly important for prestressed concrete bridges and for structures such as car parks where the use of de-icing salts leads to a high risk of corrosion of embedded steel (both reinforcement and prestressing). Concrete Society Technical Report 72, Durable post-tensioned concrete structures, provides engineers with authoritative, practical guidance on designing, specifying and constructing durable post-tensioned concrete bridges.

jonnyhough

jonnyhough

Benefits of prestressing

The main benefit of prestressing is that the build up of tension under service loads and possible cracking may be avoided or reduced to a low level. The effective stiffness of the cross-section is increased, leading to a reduction in deflections. This is particularly important for long-span structures and results in lower overall depths. Deflected tendons can enhance the shear capacity of sections, with the vertical component of the prestressing force carrying a proportion of the load. Prestressing should enhance the fatigue resistance of structures subjected to repeated loads, such as bridges. Finally, prestressing is beneficial in many forms of segmental construction

jonnyhough

jonnyhough

Pre-tensioning concrete.

In pre-tensioning the prestressing tendons are tensioned and anchored between fixed supports before the concrete is cast. The concrete is either cast in moulds or formed by an extrusion or slip-form process to form the required cross-section. When the concrete has gained sufficient strength, the tendons are released from the supports. The prestressing force is transferred from the tendons to the concrete by the bond between the tendon and concrete. The transfer occurs over a short transmission length at each end of the concrete member. Elastic shortening of the member will lead to some loss of the prestressing force.

jonnyhough

jonnyhough

Post-tensioning concrete

In post-tensioning, the prestressing tendons, which may be located inside or outside the concrete, are tensioned after the concrete has hardened. Internal tendons are contained within ducts or sheaths cast into the concrete and can be arranged to follow the most appropriate profile to suit the applied external loading. External tendons are arranged in a series of straight lines with changes of direction at specific locations. In all cases the tendons are tensioned using jacks that bear against the exposed face of cast-in anchorages at the ends of the tendon. When the required force has been attained, the tendons are secured at the anchorages, using a system of wedges. The elastic shortening of the concrete that occurs during the tensioning process has no effect on the force in the tendons, but some loss may occur due to draw-in of the anchoring wedges.

jonnyhough

jonnyhough

Steel strand & wire

High-strength steel wire is available (with a characteristic strength in the order of 1800 N/mm2) may be used for prestressing. However, it is more usual for several wires to be formed into a strand, the most common being 7-wire strand although 5-wire and 19-wire are available from some suppliers.

jonnyhough

jonnyhough

High tensile bars

As an alternative to wires or strand, high tensile steel bars may be used. (These are obviously significantly stiffer and hence may only be used in situations in which the prestressing force runs in a straight line.) Bar diameters range from 25 mm to 75 mm, with characteristic strengths in the region of 1000 N/mm2. The bars are supplied in standard lengths with rolled threads on the ends.

jonnyhough

jonnyhough

Prestressing design

The basic design principle is that the prestressing force is provided to counteract the tensile forces induced in the concrete member by externally applied loads. The strands or wires are generally located within the member but may be located outside it. The prestressing may be applied before the concrete hardens (pre-tensioning) or after it has gained sufficient strength (post-tensioning).

jonnyhough

jonnyhough

Basis of prestressed concrete design

The basic principle of prestressed concrete design is that some or all of the concrete cross-section is put into compression during the construction process. The arrangement of pre-compression is such that those areas of the structure that would be expected to go into tension under the loads applied in service (such as the sagging regions of beams) still remain in compression (or in very limited tension).

jonnyhough

jonnyhough

FRP prestressing tendons

FRP (Fibre Reinforced Plastic) prestressing tendons consist of high strength/high stiffness carbon, glass or aramid fibres combined with a suitable resin, generally epoxy-based. Typical properties are given in the Table. FRP tendons require special anchors, generally resin-filled

jonnyhough

jonnyhough

This website uses cookies to improve your web experience.