How do I carry out large area pours for suspended slabs?
Large area pours for suspended slabs improve both productivity and quality
Large area pours for suspended slabs improve both productivity and quality
Approved Documents (AD) provide guidance for the implementation of Building Regulation requirements.
Early age thermal shrinkage of cold store floors can be reduced by following a programme of cooling the enclosed environment to the operating temperature.

Wimpey no fines concrete is a system of housing developed by George Wimpey and Co. using no fines concrete and traditional construction methods.
These are covered by BS 8204, Screeds, bases and in-situ floorings, Part 1: Concrete bases and cement sand levelling screeds to receive floorings– code of Practice (2004).

These are covered by BS 8204, Screeds, bases and in-situ floorings, Part 1: Cementitious levelling screeds and wearing screeds– code of Practice (2004).
These are covered by BS 8204, Screeds, bases and in-situ floorings, Part 4: Cementitious terrazzo wearing surfaces – code of Practice (2004).
These are covered by BS 8204, Screeds, bases and in-situ floorings, Part 2: Concrete wearing surfaces– code of Practice (2004).
Magnesite flooring is not commonly used at the current time but was very popular for domestic applications in the period 1920 to 1940, and for Local Authority housing between 1945 and 1960. It is usually a reddish pink colour although some floors were coloured using pigments. It was commonly applied on top of concrete ground floor slabs. Magnesite flooring was made from a mixture of calcined magnesite and magnesium chloride solution with various fillers (e.g. wood flour, sawdust, asbestos). It was typically laid between 10 and 25mm thick, but two coat applications could be up to 50mm thick. Magnesite floorings are very vulnerable to dampness and if there is any doubt about moisture protection, it should be replaced. Chlorides may migrate from the magnesite into the concrete below and corrode any reinforcement or gas and water pipes. Most magnesite floors are now coming to the end of their life, only if they can be guaranteed to remain unaffected by moisture can they be used as a screed to receive other floorings, otherwise the flooring should be replaced.
Identification: It is easy to confuse magnesite with a pigmented sand/cement screed
These are covered by BS 8204, Screeds, bases and in-situ floorings, Part 3: Polymer modified cementitious screeds and wearing screeds – code of Practice (2004).